Data Center Smart Hands

Smart hands coverage for colocation and carrier facilities. We take direction from your remote engineers over secure channels to perform hardware swaps, upgrades, and remediation on production servers — without dropping uptime or stepping outside the change window.

Scopes it runs at
3
Steps in a job
3
Deliverables
5
Estimate
$0

Scope

What this looks like at your scale

Your infrastructure is in a facility you cannot reach quickly, and something needs a pair of hands in front of it. The work itself is rarely difficult; what matters is that it is done exactly as directed, in the right cage, on the right unit, with the change window respected and the person on the bridge told what is actually being seen rather than what was expected.

  1. 01

    A single dispatch

    A reboot, a media swap, a cable trace, a console session. Scheduled or same-day where the day still has hours in it.

  2. 02

    A rack build

    Rack and stack, power and network cabling, labelling, and photographs of the finished elevation.

  3. 03

    A migration or decommission

    Moving or removing equipment across a change window, with an asset record and a disposal chain for what comes out.

How it runs

In the order the work happens

The sequence matters more than the list. Most of what goes wrong on these jobs traces back to a step skipped early rather than to the work itself.

  1. 01

    Confirm access and protocol before travelling

    Facility access list, escort requirement, cage and rack identifiers, and the change reference. Arriving without one of those is a wasted trip somebody pays for.

  2. 02

    Work on the bridge, describing what is there

    The value of remote hands is accurate eyes. What the indicator actually shows, what the label actually says, what is actually cabled where — rather than confirmation of what the person on the call expects.

  3. 03

    Photograph before and after

    Every change recorded visually, so the state before is available if a rollback is called for and the state after is not something anybody has to take on trust.

What you get

What is actually delivered

  • Drive, PSU, NIC, and DIMM replacement on live hosts
  • Console and out-of-band access for remote engineers
  • Optic, patch, and cross-connect changes
  • Photo verification and ticket-grade documentation
  • Escorted access under facility security protocol

Not this

What we do not do here

Stating this is what makes the rest of the page worth believing, and it saves you a call that was never going to end in work.

  • Operating system and application administration. We are hands in the facility rather than a systems administration contract.
  • Facility-side power, cooling and cross-connect provisioning, which belong to the colocation provider.
  • Anything outside the change window and the written instruction — we will raise it on the bridge rather than improvise.

Questions

Before you call

Can you work under our change control?
Yes, and we expect to. Escorted access, a live bridge, a stated window and a written instruction is the normal shape of this work, and we document what was touched.
Which facilities do you cover?
The New York metro as standard. Anything beyond that radius is quoted case by case, and we will be straightforward about whether the travel makes sense.

Related

Usually bought alongside

Next step

Need Data Center Smart Hands?

Free diagnostics and a written estimate before anyone is dispatched. Tell us the site and the deadline and we will tell you what it takes.

Or call and speak to someone who does the work(347) 262-9435inquiries@jcitsystems.com
  • Free diagnostics
  • Same-day across most of the metro
  • Named technicians
  • No fix, no labour charge